As has been demonstrated throughout this radiation safety course, scientific and mathematical principals are the tools we use to determine what exactly is a safe Time or Distance as it relates to radiation exposure. Less shielding and distance are needed but more exposure time is needed to take the same radiographs.ĪLARA: maintaining our individual radiation exposure to “As Low As is Reasonably Achievable” involves the principals of Time, Distance and Shielding. Now, let’s just fast forward the scenarios above 74.3 days (the half-life of Ir-192) and now our 100 ci source has decayed to 50 ci from the original 100 ci source, all of the safety protocols and exposure times have changed. Radiographers have the task of taking pictures – radiographs – of whatever job they are working (Aerospace parts, oil line pipe welds, bridge structures, nuclear cooling tubes, etc.) As in the safety protocols in item #1 above, radiographers must calculate exposure times (how long to expose film and DDA’s to the gamma radiation).
![half life symbol half life symbol](https://i.pinimg.com/originals/bc/b6/fb/bcb6fbf770aac36b1b2178bf45d3d68e.jpg)
Appropriate shielding and safe distances (ALARA) will be calculated based on these calculated numbers. For example, if a radiographer is using a 100-curie (ci) source of Iridium – 192 to take radiographs, the technician will know 5.2 R/h are emitted for each ci at 1 foot therefore, a little math tells us that 100ci source multiplied by 5.2 R/h/ci has a total of 520 R/h. This can only be accomplished if the number of curies of the source is known. The radiographer’s safety protocols are dependent on calculating safe distances (Inverse Square Law Formula) and known radiation emissivity at any given distance from the gamma source.So why does the radiographer care about half-life? There are two reasons: Rutherford applied the principle of a radioactive element’s half-life to studies of age determination of rocks by measuring the decay period of radium to lead-206. The original term, half-life period, dating to Ernest Rutherford’s discovery of the principle in 1907, was shortened to half-life in the early 1950s.
![half life symbol half life symbol](https://logos-download.com/wp-content/uploads/2018/04/Half_Life_logo_2.png)
For example, the medical sciences refer to the biological half-life of drugs and other chemicals in the human body. The term is also used more generally to characterize any type of exponential or non-exponential decay.
![half life symbol half life symbol](https://m.media-amazon.com/images/I/91BORDcUkRL._AC_SX450_.jpg)
The term is commonly used in nuclear physics to describe how quickly unstable atoms undergo, or how long stable atoms survive, radioactive decay. Half-life (symbol t1⁄2) is the time required for a quantity of an isotope to reduce to half its initial value. To help define and quantify this dilemma, the radioactive Half-Life is as follows: One phenomena radiographers deal with is how rapidly the rate of decay affects the usefulness and associated hazards of a radioactive isotope. In addition, there is less self-absorption in high specific activity sources because there is less matter to attenuate or absorb the radiation.
![half life symbol half life symbol](https://uploads.turbologo.com/uploads/design/hq_preview_image/1544528/draw_svg20210507-22909-trpxok.svg.png)
Curies per gram or Becquerel’s per gram)Ī high specific activity indicates that a source of a given activity will have a smaller physical size (smaller focal spot) which will yield better definition with radiographs. Specific Activity: The specific activity of an isotope is used to describe the activity per unit of mass or weight (i.e. In the SI system, the Becquerel (Bq) is the unit of activity, which is equal to one disintegration per second. One curie equals 37,000,000,000 (37 billion) disintegrations per second. Activity: Named after Nobel Prize recipient Marie Curie, the curie (ci) is the unit used to describe the rate of decay or activity, of a radioactive material in disintegrations per second.